AZIC900-502 Coriolis Mass Flowmeter

AZIC900-502 Coriolis Mass Flowmeter with MODBUS RTU Communication Protocol output signal

AZIC900-502 Coriolis Mass Flowmeter

Specification

Diameter: U-type: DN20~DN150; 

Triangular: DN3~DN15; 

Straight Tube: DN8~DN80 

Measurand: Mass flow, density, temperature 

Density accuracy: earth 0.002g/cm³ 

Accuracy: 0.1%, 0.15%, 0.2% 

Temperature: -40℃

Characteristics

MODBUS RTU Communication Protocol

Convenient Human-Machine Interface

Temperature and Pressure Compensation

Directly Measurable

Small Amplitude of the Measuring Tube

Specification

Diameter

U-type: DN20~DN150; Triangular: DN3~DN15; Straight Tube: DN8~DN80

Measurand

Mass flow, density, temperature

Density accuracy

earth 0.002g/cm³

Accuracy

0.1%,0.15%,0.2%

Temperature

-40~+60℃

Power consumption

<15W

Power supply

220 VAC;   24VDC

Signal output

4~20mA, RS485, HART

Ingress protection

IP67

Density range

(0.3~3.000)g/cm³

Repeatability

1/2 of the measurement error

Medium temperature

Standard type: (-50~200)℃, (-20~200)℃; High-temperature type: (-50~350)°C; Low-temperature type: (-200~200)°C

Process pressure

(0~4.0)MPa

Humidity

35%~95%

Transmission output

(4–20) mA, output load (250–600) Ω

AZIC900-502 Coriolis Mass FlowmeterAZIC900-502 Coriolis Mass FlowmeterAZIC900-502 Coriolis Mass Flowmeter